Reeling Cable Flex PUR HF/FR
Application:
The reeling cable flex PUR HF/FR cables are suitable for movable facilities such as movable cranes for container, lifts, movable bigger facilities, grab dredgers and the sites of machinery stress caused by mining on the ground/well bottoms.
Standard:
Flame-retardant: VDE 0482-332-1-2/IEC 60332-1-2
Oil-resistant: EN 60811-2-1
Construction:
Conductor: bare copper wire , flexible ,class5
Insulation: XLPE
Reinforce Core: High Tension Soft Textile Material
Inner sheath: Polyurethan , Yellow
Reinforce Layer: Braiding , High Tension Soft Textile Material
Outer Sheath: Polyurethan , Yellow
Core identification: colours acc. to VDE 0293 (HD308)
Technical data:
Rated voltage: 0.6/1KV
Max. Conductor operating Temperature: 90 °C
Permitted outer cable temperature, fixed, °C: -40 - +80 °C
Permitted outer cable temperature, moved, °C: -30 - +80 °C
Bending radius: fixed installation: 6 D , moving application 8D
Maximum tensile strength at the conductor: 25 N/mm²
Operating speed random, m/min.: 180 m/min.
Operating speed festoon, m/min.: 200 m/min.
PUR HF FR
Part Name |
Outer diameter approx(mm) |
Net weight per 1000m(kg) |
---|---|---|
03X25 + 3G6 + 2X1.5 |
27 |
1250 |
03X35 + 3G6 + 2X1.5 |
29.3 |
1550 |
03X50 + 3G10 + 2X1.5 |
33.5 |
2300 |
03X70 + 3G16 + 2X1.5 |
38.5 |
3150 |
03X95 + 3G16 + 2X1.5 |
42.5 |
3850 |
03X120 + 3G25 + 2X1.5 |
46.5 |
5100 |
03X150 + 3G25 + 2X1.5 |
54 |
6100 |
03X185 + 3G35 + 2X1.5 |
58.5 |
7200 |
03X240 + 3G50 + 2X1.5 |
63.5 |
8950 |
03X25 + 3G6 + 2X2.5 |
27 |
1313 |
03X35 + 3G6 + 2X2.5 |
29.3 |
1628 |
03X50 + 3G10 + 2X2.5 |
33.5 |
2415 |
03X70 + 3G16 + 2X2.5 |
38.5 |
3308 |
03X95 + 3G16 + 2X2.5 |
42.5 |
4043 |
03X120 + 3G25 + 2X2.5 |
47 |
5540 |
03X150 + 3G25 + 2X2.5 |
54 |
6450 |
03X185 + 3G35 + 2X2.5 |
58.5 |
7560 |
03X240 + 3G50 + 2X2.5 |
63.5 |
9398 |
04G16 |
22 |
860 |
XLPE stands for cross-linked polyethylene, a type of thermosetting plastic that has high resistance to heat, abrasion, moisture, and chemicals.
PUR stands for polyurethane, a type of polymer that has high flexibility, durability, abrasion resistance, and flame retardance.
HF/FR stands for halogen-free flame retardant, a type of material that does not emit toxic or corrosive gases when exposed to fire.
The cross-sectional area of a conductor is the area of a circle with the same diameter as the conductor. It can be calculated by using the formula A = πr², where A is the area, π is approximately 3.14, and r is the radius (half of the diameter) of the conductor.
The cable size depends on several factors, such as voltage drop, current rating, short circuit rating, and environmental conditions. You can use online calculators or tables to find out suitable cable sizes for your application based on these factors.